Model No.︰APX503
Brand Name︰-
Country of Origin︰China
Unit Price︰CNY ¥ 700 / pc
Minimum Order︰1 pc
Tuning Fork Level Switch
User Manual
Ø First. Introduction
This product is based on liquid point level switch vibration short fork technology. It is a compact switch with durable stainless steel body and a fork can be used for a variety of liquid applications. An "economic level switch through the threaded mounting pipe or tank, or by health fittings installed in the food industry facilities directly applicable to all power load switch or PNP output, used as a programmable logic controller (PLC) direct interface provided to prevent overflow certification applies only to a safe area.
Ø Second, product characteristics
1.Run a real impact by free flow, turbulence, bubbles, foam, vibration, solids content, coating, liquid properties and product changes
2.does not require calibration and installation procedures required minimum 3.polarity insensitive and short circuit protection
4.The use of industry-standard plug / socket connector 5.No moving parts or gaps truly maintenance-free
6.electronic components, self-test, and status monitoring -LED display status information and good information 7.facilitate magnetic test point for functional testing
8.The compact design of the compact and light weight
9."fast low" the fork design for the replacement of a viscous liquid having a response time 10. The sanitary fittings.
Ø Third, the measurement principle
This product is a tuning fork design principles using liquid level switch. Piezoelectric crystal to the natural frequency of the tuning fork vibration of a tuning fork. For the change in frequency can be continuously monitored. When the product is used as a low alarm, the liquid in the vessel drains down past the fork, causing the natural frequency changes, this change is detected by the electronics, thereby switching the output state. When used in high alarm, the liquid in the container rises in contact with the fork again the output switches.
Selecting the natural frequency of the tuning fork (about 1300Hz), a device to prevent the interference of vibration, which may cause false switching operation, the length of the tuning fork so that the length of the shorter pipe extends into the container or the shortest, due to the design of the product with short fork technology, can be used in virtually all liquid applications. Numerous studies have been designed to make the fork to the highest operating frequency, so that the product is suitable for all liquids, including coating liquids (avoid bridging of forks), aerated liquids and slurries.
Ø Fourth, application examples
Prevent overflow
In charge will spill over human and environmental harm caused by full,resulting in loss of production and increased cleaning costs, change device is a limit switch, readily available for overflow signal.
Pump Protection
Short Fork wet side of the insertion length of the shortest, and can be easily installed at any angle in the pipe or vessel, thus reducing installation costs. With the fork projecting only 2 inches (50mm) (depending on the connection type), the device can even be installed on small diameter pipes, direct load switch by selecting the option of electronic components, equipment, ideal for reliable pump control, and the available to prevent the pump running dry.
High and low level alarm
The product is room to store all kinds of the highest and lowest level of detection of different liquids storage; the ideal choice. Ruggedized device can run continuously at temperatures up to 302 ° F (150 ℃) environment and operating pressure up to 1450psig (100barg), making it especially suitable for high-level alarm. Customary practice is to install a separate high-level alarm switch, so that in case of failure to provide additional standby switch.
Leak Detection
Flanges, gaskets, seals ,, a corrosive liquids under adverse conditions, they are likely to leak. Most users of the site tanks and container is mounted on the base plate or in the protective body in order to prevent liquid leakage. The product can be quickly and accurately detect any leakage, so the cost can be significantly reduced.
Pump Control
Many parts have a batch process and elevated storage tanks,usually need to control the pump to reach the level set point. These tanks are usually fabricated with materials thinner, and therefore can not withstand heavy instrument.
Health Applications
Due to the highly polished surface finish provides a tuning fork (Ra) better than 0.8um, the product meets the basic design of the standard diet and pharmaceutical applications with the most stringent requirements. Better than stainless steel, the product has sufficient durability, can withstand routine steam cleaning at temperatures up to 302 °F (150 ℃) when the (cleaning in place CIP).
Ø Fifth.Application and Installation Best Practices
Application Considerations
Ø Six recommended installation
Ø Seven. technical specifications
Physical Characteristics
Performance
Features
19.CIP (cleaning in place) cleaning can withstand temperatures of up steam cleaning routine 302 "F (150 ℃) Features
22. The maximum wire size 0.06 inches (1.5mm²)
25. The electronic component connection 15V-28V DC power supply for the product standard two-wire cable connected in series with the load and achieve direct load switch. Output acts as a simple single-pole, single-throw (SPST) switch, with the emergence of the liquid is changed. The most options, you can use 24V DC solid state PNP output, as a programmable logic controller (PLC) direct interface. Simultaneously with relay output current capacity, up to 5A.
Ø Eight,electricalconnectiondiagram
Payment Terms︰ TT